Difference between revisions of "MC-Basic:axis.VELOCITYEXTERNALFACTOR"
m |
|||
(4 intermediate revisions by one other user not shown) | |||
Line 1: | Line 1: | ||
+ | {{Languages|MC-Basic:axis.VELOCITYEXTERNALFACTOR}} | ||
{{MC-Basic | {{MC-Basic | ||
|SHORT FORM= | |SHORT FORM= | ||
Line 39: | Line 40: | ||
|SEE ALSO= | |SEE ALSO= | ||
− | * [[ | + | * [[MC-Basic:axis.POSITIONEXTERNAL|axis.POSITIONEXTERNAL]] |
− | * [[ | + | * [[MC-Basic:axis.POSITIONEXTERNALFACTOR|axis.POSITIONEXTERNALFACTOR]] |
− | * [[ | + | * [[MC-Basic:axis.VELOCITYEXTERNAL|axis.VELOCITYEXTERNAL]] |
}} | }} |
Latest revision as of 09:55, 21 April 2017
Language: | English • 中文(简体) |
---|
The velocity factor of the external feedback is used to convert that value from counts per millisecond into physical units.
Short form
<axis>.VExtFac
Syntax
<axis>.VelocityExternalFactor = <expression>
?<axis>.VExtFac
Availability
All versions
Type
Double
Range
Greater than 0
Default
1
Scope
Configuration, Task or Terminal
Limitations
Cannot be changed while axis is enabled or while axis is set up as a master axis.
Examples
If the feedback resolution is 2000 counts, and you want to work in RPM, the VFAC is set as:
- Xaxis.vExtFac = 2000/60000
- Xaxis.vExtFac = 2000/60000
To work in revolutions per second, the VFAC must be set as:
- Xaxis.VExtFac = 2000/1000