Difference between revisions of "MC-Basic:axis.CAMVALUE"
(5 intermediate revisions by 2 users not shown) | |||
Line 1: | Line 1: | ||
+ | {{Languages|MC-Basic:axis.CAMVALUE}} | ||
{{MC-Basic | {{MC-Basic | ||
|SHORT FORM= | |SHORT FORM= | ||
Line 10: | Line 11: | ||
|DESCRIPTION= | |DESCRIPTION= | ||
− | This property is used to query the current value of the master data in the | + | This property is used to query the current value of the master data in the cam table. The current value of the master data in the table is the value being accessed at the time of the query. |
|TYPE= | |TYPE= | ||
Line 28: | Line 29: | ||
|LIMITATIONS= | |LIMITATIONS= | ||
− | Read | + | Read only |
|EXAMPLE= | |EXAMPLE= | ||
Line 34: | Line 35: | ||
|SEE ALSO= | |SEE ALSO= | ||
− | * [[ | + | * [[MC-Basic:cam.MASTERDATA|cam.MASTERDATA]] |
}} | }} |
Latest revision as of 09:39, 17 April 2017
Language: | English • 中文(简体) |
---|
This property is used to query the current value of the master data in the cam table. The current value of the master data in the table is the value being accessed at the time of the query.
Short form
<axis>.CVAL
Syntax
?<axis>.CamValue
Availability
All versions
Type
Double
Range
± MaxDouble
Scope
Configuration, Task or Terminal
Limitations
Read only
Examples
?Axis1.Cval