Difference between revisions of "MC-Basic:cam.CYCLE"
m (Text replace - "''<cam>''" to "<''cam''>") |
|||
| (5 intermediate revisions by 2 users not shown) | |||
| Line 1: | Line 1: | ||
| + | {{Languages|MC-Basic:cam.CYCLE}} | ||
{{MC-Basic | {{MC-Basic | ||
|SHORT FORM= | |SHORT FORM= | ||
| Line 12: | Line 13: | ||
|DESCRIPTION= | |DESCRIPTION= | ||
| − | This property sets the number of cycles for which the | + | This property sets the number of cycles for which the cam table is to be executed. A cam table is repeated when the master passes the end of the table and the number of cycles is a value greater than 1. Setting the number of cycles to the value -1 enables the table to be repeated continually. The number of cycles is changed while camming is enagaged. |
|TYPE= | |TYPE= | ||
| Line 36: | Line 37: | ||
|SEE ALSO= | |SEE ALSO= | ||
| − | * [[ | + | * [[MC-Basic:axis.ACTIVECAM|axis.ACTIVECAM]] |
| − | * [[ | + | * [[MC-Basic:axis.CAMCYCLE|axis.CAMCYCLE]] |
}} | }} | ||
Latest revision as of 07:44, 25 April 2017
| Language: | English • 中文(简体) |
|---|
This property sets the number of cycles for which the cam table is to be executed. A cam table is repeated when the master passes the end of the table and the number of cycles is a value greater than 1. Setting the number of cycles to the value -1 enables the table to be repeated continually. The number of cycles is changed while camming is enagaged.
Short form
Cyc
Syntax
<cam>.Cycle = <number of cycles>
?<cam>.Cycle
Availability
All versions
Type
Long
Range
-1, 1 to MaxLong
Default
1
Scope
Configuration, Task or Terminal
Examples
Cam1.Cycle = -1