Difference between revisions of "MC-Basic:axis.CountExtMax"
m (Text replace - "''<axis>''" to "<''axis''>") |
|||
(16 intermediate revisions by 2 users not shown) | |||
Line 1: | Line 1: | ||
+ | {{Languages|MC-Basic:axis.CountExtMax}} | ||
{{MC-Basic | {{MC-Basic | ||
|SHORT FORM= | |SHORT FORM= | ||
|SYNTAX= | |SYNTAX= | ||
− | <''axis''>.CountExtMax = '' | + | <''axis''>.CountExtMax = <''value''><br> |
?<''axis''>.CountExtMax | ?<''axis''>.CountExtMax | ||
|AVAILABILITY=From ver 4.7.13 | |AVAILABILITY=From ver 4.7.13 | ||
− | |DESCRIPTION={{ | + | |DESCRIPTION={{CountMinMax}} |
This property indicates the maximum counts value of the drive (external). | This property indicates the maximum counts value of the drive (external). | ||
− | |TYPE= | + | |TYPE= integer |
|RANGE= min-max integer | |RANGE= min-max integer | ||
|UNITS= counts | |UNITS= counts | ||
− | |DEFAULT= 2 | + | |DEFAULT= 2<sup>31</sup> - 1 |
|SCOPE=Configuration, Task or Terminal | |SCOPE=Configuration, Task or Terminal | ||
− | |LIMITATIONS= Modal | + | |LIMITATIONS= |
+ | *Modal | ||
+ | *Axis only | ||
+ | *Drive must be disabled | ||
|EXAMPLE= | |EXAMPLE= | ||
|SEE ALSO= | |SEE ALSO= | ||
− | * [[ | + | * [[MC-Basic:axis.CountMin|axis.CountMin]] |
− | * [[ | + | * [[MC-Basic:axis.CountMax|axis.CountMax]] |
− | * [[ | + | * [[MC-Basic:axis.CountRollOver|axis.CountRollOver]] |
− | * [[ | + | * [[MC-Basic:axis.CountExtMin|axis.CountExtMin]] |
− | * [[ | + | * [[MC-Basic:axis.CountExtRollOver|axis.CountExtRollOver]] |
− | * [[ | + | * [[Endless Axes| Infinite Axes]] |
− | {{Bugzilla|5339}} | + | <!-- {{Bugzilla|5339}} --> |
}} | }} |
Latest revision as of 03:09, 18 April 2017
Language: | English • 中文(简体) |
---|
Note that some drives (such as BRC) use standard SERCOS IDNs (76,103,278) to define modulo behavior of the motor minimum and maximum position (command and feedback).
This property indicates the maximum counts value of the drive (external).
Syntax
<axis>.CountExtMax = <value>
?<axis>.CountExtMax
Availability
From ver 4.7.13
Type
integer
Range
min-max integer
Units
counts
Default
231 - 1
Scope
Configuration, Task or Terminal
Limitations
- Modal
- Axis only