Difference between revisions of "MC-Basic:axis.CAMINDEX"

From SoftMC-Wiki
Jump to: navigation, search
m (Text replace - "''<axis>''" to "<''axis''>")
 
(5 intermediate revisions by 2 users not shown)
Line 1: Line 1:
 +
{{Languages|MC-Basic:axis.CAMINDEX}}
 
{{MC-Basic
 
{{MC-Basic
 
|SHORT FORM=
 
|SHORT FORM=
Line 10: Line 11:
  
 
|DESCRIPTION=
 
|DESCRIPTION=
This property is used to query the current index of the CAM table.The current index of the table is the row in the CAM data currently being accessed.
+
This property is used to query the current index of the cam table.The current index of the table is the row in the CAM data currently being accessed.
  
 
|TYPE=
 
|TYPE=
Line 28: Line 29:
  
 
|LIMITATIONS=
 
|LIMITATIONS=
Read-Only<br>
+
Read only<br>
  
 
The axis must be in the CAM mode of operation.
 
The axis must be in the CAM mode of operation.
Line 36: Line 37:
  
 
|SEE ALSO=
 
|SEE ALSO=
* [[Axystems:MC-Basic:CREATECAMDATA|CREATECAMDATA]]
+
* [[MC-Basic:CREATECAMDATA|CREATECAMDATA]]
  
  
 
}}
 
}}

Latest revision as of 09:25, 17 April 2017

Language: English  • 中文(简体)‎

This property is used to query the current index of the cam table.The current index of the table is the row in the CAM data currently being accessed.

Short form

<axis>.Cind

Syntax

?<axis>.CamIndex

Availability

All versions

Type

Long

Range

1 to MaxLong

Default

1

Scope

Configuration, Task or Terminal

Limitations

Read only

The axis must be in the CAM mode of operation.

Examples

?Axis1.CamIndex

See Also