Difference between revisions of "MC-Basic:axis.PIPEMODE"

From SoftMC-Wiki
Jump to: navigation, search
 
(10 intermediate revisions by 2 users not shown)
Line 1: Line 1:
 +
{{Languages|MC-Basic:axis.PIPEMODE}}
 
{{MC-Basic
 
{{MC-Basic
 
|SHORT FORM=
 
|SHORT FORM=
<Axis>.PMode
+
<''axis''>.PMode
  
 
|SYNTAX=
 
|SYNTAX=
<Axis>.PMode = ''<expression>''<br>
+
<''axis''>.PMode = <''expression''><br>
  
?<Axis>.PMode
+
?<''axis''>.PMode
  
 
|AVAILABILITY=
 
|AVAILABILITY=
Line 12: Line 13:
  
 
|DESCRIPTION=
 
|DESCRIPTION=
This property enables the axis pipe-mode operation. When axis pipe-mode is active, the position and velocity commands to the drive are taken from the Sys.HostDouble[] variables. To engage the sys.pmode should be set to ON.
+
This property enables the axis Pipe mode operation. When axis Pipe mode is active, the position and velocity commands to the drive are taken from the Sys.HostDouble[] variables. To engage, sys.pmode must be set to ON.
  
{{Note/Important| '''THIS PROPERTY IS OBSOLETE'''}}
 
  
 
|TYPE=
 
|TYPE=
Line 21: Line 21:
 
|RANGE=
 
|RANGE=
 
0 (OFF)<br>
 
0 (OFF)<br>
 
 
1 (ON)
 
1 (ON)
  
Line 34: Line 33:
  
 
|LIMITATIONS=
 
|LIMITATIONS=
 
+
* When Sys.PipeMode = 1, axes A1…A8 can operate in Pipe mode
 
+
* When Sys.PipeMode = 2, axes A1…A4 can operate in Pipe mode
When Sys.PipeMode = 1, axes A1…A8 can operate in pipe-mode.
+
*Not supported in EtherCAT system
 
 
When Sys.PipeMode = 2, axes A1…A4 can operate in pipe-mode.
 
  
 
|EXAMPLE=
 
|EXAMPLE=
<Axis>.PMode = ON
+
<''axis''>.PMode = ON
  
?<Axis>.PMode
+
?<''axis''>.PMode
  
 
|SEE ALSO=
 
|SEE ALSO=
* [[Axystems:MC-Basic:SYSTEM.PIPEMODE|SYSTEM.PIPEMODE]]
+
* [[MC-Basic:SYSTEM.PIPEMODE|SYSTEM.PIPEMODE]]
  
[[Category:Axystems:Obsolete|axis.PIPEMODE]]
+
[[Category:Obsolete|axis.PIPEMODE]]
 
}}
 
}}

Latest revision as of 03:20, 20 April 2017

Language: English  • 中文(简体)‎

This property enables the axis Pipe mode operation. When axis Pipe mode is active, the position and velocity commands to the drive are taken from the Sys.HostDouble[] variables. To engage, sys.pmode must be set to ON.

Short form

<axis>.PMode

Syntax

<axis>.PMode = <expression>

?<axis>.PMode

Availability

Versions 4.0.2 and higher

Type

Long

Range

0 (OFF)
1 (ON)

Default

OFF

Scope

Config, Task or Terminal

Limitations

  • When Sys.PipeMode = 1, axes A1…A8 can operate in Pipe mode
  • When Sys.PipeMode = 2, axes A1…A4 can operate in Pipe mode
  • Not supported in EtherCAT system

Examples

<axis>.PMode = ON

?<axis>.PMode

See Also