Difference between revisions of "MC-Basic:axis.IN3MODE"
(7 intermediate revisions by 2 users not shown) | |||
Line 1: | Line 1: | ||
+ | {{Languages|MC-Basic:axis.IN3MODE}} | ||
{{MC-Basic | {{MC-Basic | ||
|SHORT FORM= | |SHORT FORM= | ||
Line 4: | Line 5: | ||
|SYNTAX= | |SYNTAX= | ||
− | '' | + | <''axis''>.In3Mode = <''value''> |
|AVAILABILITY= | |AVAILABILITY= | ||
Line 11: | Line 12: | ||
|DESCRIPTION= | |DESCRIPTION= | ||
Specifies the functionality of the drive digital input 3.<br> | Specifies the functionality of the drive digital input 3.<br> | ||
− | + | 0 – no special function<br> | |
− | + | 1 – CW limit switch<br> | |
− | + | 2 – CCW limit switch<br> | |
− | + | 3 – reserved<br> | |
− | + | 4 – reserved<br> | |
− | + | 5 – reserved<br> | |
− | + | 6 – reserved<br> | |
− | + | 7 – reserved<br> | |
− | + | 8 – second bipolar torque limit<br> | |
− | + | 9 – reserved<br> | |
− | + | 10 – home switch<br> | |
− | + | 11 – reserved<br> | |
− | + | 12 – reserved<br> | |
− | + | 13 – reserved<br> | |
− | + | 14 – reserved<br> | |
− | + | 15 – reserved<br> | |
− | + | 16 – probe input (capture)<br> | |
− | + | 17 – reserved<br> | |
− | + | 18 – open fault relay | |
Two keyword values are defined:<br> | Two keyword values are defined:<br> | ||
− | + | * “capturing” (=16)<br> | |
− | + | * “homing” (=10) | |
+ | |||
+ | Specifying an invalid value displays the message “Incorrect parameter value”. <br> | ||
+ | Replacing a previous functionality displays the message “Input switch might have been dedicated to another function.” | ||
− | |||
− | |||
|TYPE= | |TYPE= | ||
Line 55: | Line 57: | ||
|LIMITATIONS= | |LIMITATIONS= | ||
− | Each function input may be assigned only 1 digital value | + | * Each function input may be assigned only 1 digital value |
+ | * Valid in communications phase 2 or higher | ||
+ | *Not supported in EtherCAT system | ||
|EXAMPLE= | |EXAMPLE= | ||
Line 63: | Line 67: | ||
|SEE ALSO= | |SEE ALSO= | ||
− | * [[ | + | * [[MC-Basic:axis.IN3|axis.IN3]] |
− | [[Category | + | [[Category:Obsolete|axis.IN3MODE]] |
}} | }} |
Latest revision as of 09:45, 19 April 2017
Language: | English • 中文(简体) |
---|
Specifies the functionality of the drive digital input 3.
0 – no special function
1 – CW limit switch
2 – CCW limit switch
3 – reserved
4 – reserved
5 – reserved
6 – reserved
7 – reserved
8 – second bipolar torque limit
9 – reserved
10 – home switch
11 – reserved
12 – reserved
13 – reserved
14 – reserved
15 – reserved
16 – probe input (capture)
17 – reserved
18 – open fault relay
Two keyword values are defined:
- “capturing” (=16)
- “homing” (=10)
Specifying an invalid value displays the message “Incorrect parameter value”.
Replacing a previous functionality displays the message “Input switch might have been dedicated to another function.”
Syntax
<axis>.In3Mode = <value>
Availability
All versions
Type
Long
Range
0 to 18
Default
Dependent on the drive
Scope
Task or Terminal
Limitations
- Each function input may be assigned only 1 digital value
- Valid in communications phase 2 or higher
- Not supported in EtherCAT system
Examples
?a1.In3Mode
a1.in3Mode = homing