| − | Defines the translation deceleration of the robot. Together with DROT, defines the decleration of a Cartesian motion. This value is used only in two motion commands: MOVES and CIRCLE. In joint interpolated movements (MOVE), this value is ignored. The group must be defined with a robot model (model !=1). The value cannot be greater than | + | Defines the translation deceleration of the robot. Together with DROT, defines the decleration of a Cartesian motion. This value is used only in two motion commands: MOVES and CIRCLE. In joint interpolated movements (MOVE), this value is ignored. The group must be defined with a robot model (model !=1). The value cannot be greater than [[MC-Basic:movingFrame.ACCELERATIONMAXTRAN|ACCELERATIONMAXTRANS]]. The system always takes the smaller of the two with a notification message sent to the user. |
|TYPE= | |TYPE= | ||
Revision as of 13:58, 16 June 2025
| Language: | English • 中文(简体) |
|---|
Defines the translation deceleration of the robot. Together with DROT, defines the decleration of a Cartesian motion. This value is used only in two motion commands: MOVES and CIRCLE. In joint interpolated movements (MOVE), this value is ignored. The group must be defined with a robot model (model !=1). The value cannot be greater than ACCELERATIONMAXTRANS. The system always takes the smaller of the two with a notification message sent to the user.
Short form
<ROBOT>.dtran
Syntax
<ROBOT>.dtran=<numeric expression>
Type
double
Range
0.1-maxdouble
Units
mm/sec2
Default
1e5
Scope
Configuration, Task, Terminal
Limitations
Read/Write, Modal/Nodal
Examples
dtran = 6000