Difference between revisions of "MC-Basic:SYSTEM.ANOUT.sim"
(Created page with "{{Languages|MC-Basic:SYSTEM.ANOUT.sim}} {{MC-Basic |SHORT FORM= Sys.AnOut[Index].sim<br> |SYNTAX= ?System.AnOut[Index]sim<br> |AVAILABILITY= Version 0.4.20.5r8-C2 or higher...") |
(No difference)
|
Revision as of 13:43, 31 December 2020
| Language: | English |
|---|
Exactly the same as Sys.ANIN[Index].sim
Used to set an analog Output as simulated. Once an output was set as simulated, there is no meaning to all other analog properties.<be> The analog output becomes a simple double variable that holds a certain value regardless of its real arrangement in the digital infrastructure. Any index can be set as simulated in the analog array.
Short form
Sys.AnOut[Index].sim
Syntax
?System.AnOut[Index]sim
Availability
Version 0.4.20.5r8-C2 or higher
Type
long
Range
1 or 0
Default
no default value. depends on user configuration.
Scope
Configuration, Task or Terminal
Limitations
Read or write.
Examples
- -->Sys.AnOut[1].sim = 1