This property sets the number of cycles for which the cam table is to be executed. A cam table is repeated when the master passes the end of the table and the number of cycles is a value greater than 1. Setting the number of cycles to the value -1 enables the table to be repeated continually. The number of cycles is changed while camming is enagaged.

Short form

Cyc

Syntax

<cam>.Cycle = <number of cycles>

?<cam>.Cycle

Availability

All versions

Type

Long

Range

-1, 1 to MaxLong

Default

1

Scope

Configuration, Task or Terminal

Examples

Cam1.Cycle = -1